The following Event Types are available:
NOTE: Input Trigger and Soft Trigger are the only Event Types available on exacqVision Start systems.
Event Type
Description
Video Motion
Camera detects motion.
Video Loss
Analog video signal is disconnected.
Input Trigger
Discrete input on hybrid server or IP camera with alarm input is activated.
Serial Port
Key word entered on Serial Profile page is detected on a pre-selected port.
Serial Profile
Key word is detected on any Serial Port with that profile.
Health
Detected problem involving the health of the exacqVision server hardware.
IP Camera Connection
Network can’t connect to the IP Camera.
Soft Trigger
Signal sent from the client to the server.
Time Trigger
Time of day or day of week reached.
Analytics
Video analytics event detected.
Source Group
Multiple event types for advanced event linking.
The Event Source list varies depending on the Event Type selected:
Event Type Selected
Event Source
Video Motion
Any of the cameras connected to the exacqVision server.
Video Loss
Any analog camera connected to the exacqVision server.
Input Trigger
Any input trigger on the back of the server or IP camera connected to the
server. The system defaults to a device and input number, but these can be
customized on the Trigger Input page. See the “Trigger Inputs” section of this
manual for details.
Serial Port
Any of the serial ports configured on the server. See the “Serial Ports” section
of this manual for details.
Serial Profile
Any of the serial profiles you have configured. You can select all key words
and rules associated with a serial profile by selecting the profile name, or you
can select an individual key word or rule configured in the profile.
Health
Includes failures or temperature problems on a device; problems with storage
configuration; subscription expiration; video throttling alarms; alarms related
to parameters monitored on the Hardware Monitoring tab on the System
page; failed connection to shared network drive for archiving.
IP Camera Connection
Any of the IP cameras connected to the exacqVision server.
Soft Trigger
Select New to create a new soft trigger with a default name. Double-click to
name it, or click Delete to remove it. You can also select any of the pre-
configured soft triggers that are listed.
Time Trigger
Select New to open a window. Name the time trigger, select a start and end
time, and select the days of the week when the selected action should occur.
(For example, you could perform an Auto Export at 2:00 every morning.)
Analytics
A list of video analytics events (configured through the provider’s interface).
Source Group
Select New to open a window. You can then select any combination of event
types and event sources and determine whether any or all of them must
occur to trigger the selected action.