Exacq exacqVision Pro User Manual Manuel d'utilisateur Page 46

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 134
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 45
46
www.exacq.com
Serial Ports
The Serial Ports page allows you to configure serial ports on your exacqVision system so that they can be used to
communicate with serial devices such as POS terminals or pan-tilt-zoom (PTZ) cameras. There are two Serial Ports
sections one for standard UART (Universal Asynchronous Receiver/Transmitter) and one for serial ports over IP.
For a UART serial port, connect the wires to the serial port and then configure the port. The system automatically detects
and displays the serial ports. You can configure the following settings on each port:
1. Enter a unique name in the Name field.
2. Select the intended use of the serial port from the drop-down list in the Use column. The choices are unused,
PTZ (pan/tilt/zoom), POS (point of sale), ATM (automatic teller machine), or Access Ctrl. Generally, the POS
mode is used to record transactions at a cash register. By default, the last serial port listed is the built-in RS-485
port.
3. The Port is automatically selected by the Operating System.
4. The Profile/Protocol column allows you to select one of the profiles configured on the Serial Profile page. If you
haven’t created the appropriate profile, select New. If you select New, the Serial Profiles page will automatically
open after you complete the port configuration, and then you can create the profile.
5. The Baud Rate, Data Bits, Stop Bits, Parity, and Flow Control must match the device you are connecting to. See
the device’s documentation for more information.
6. The Max Line Length is 80 by default. Generally, you should not change this.
7. Line Ending is the number of characters received before an end-of-line character is inserted automatically. This
prevents lines from becoming extremely large.
8. Timeout is the number of seconds after which an end-of-line character is entered if a serial device has not sent
text. This is useful if the serial data does not have an end-of-line character but it hasn’t reached the number of
characters entered in Line Ending.
9. The Status column displays the current status of the serial port.
10. When you are finished, save the settings by clicking the Apply button at the bottom of the page.
The IP section is explained on the following page.
1
2
3
1
4
5
6
7
10
8
9
Vue de la page 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 133 134